PPENDICES
(g) MR-J2HBUS M-A
1) Model explanation
05
1
5
0.5(1.64)
1(3.28)
5(16.40)
Symbol
Type: MR-J2HBUS M-A
Cable length [m(ft.)]
2) Connection diagram
When fabricating a cable, use the recommended wire given on
APPENDIX 1.1, and make the cable as show in the following
connection diagram. The overall distance of SSCNET cables is
30m(98.43ft.) .
PCR-S20FS (connector)
1
11
2
12
4
14
6
16
1
15
7
17
LG
LG
RD
RD*
TD
TD*
EMG
EMG*
SD
5
15
LG
LG
14
11
2
12
4
5
20
10320-3210-000 (shell kit)
MR-J2HBUS M-A
shell
PCR-LS20LA1 (connector case)
10120-6000EL (connector)
LG
LG
RD
RD*
TD
TD*
EMG
SD
LG
LG
EMG*
:Twisted pair cable